EPA Method 1006


EPA Method 1006 does not directly match ALS - Columbia's list of currently available methods. Please call for availability.


Method information displayed is provided for informational purposes only. No warranty (express or implied) is made as to the website accuracy, completeness, or applicability (such as the age of a method and whether or not it applies to your project). Please contact us for assistance. Analytical testing dots

PDF IconView Actual EPA Method 1006 (PDF File)


EPA Method 1006:
Larval Survival and Growth Test for Waters Using Inland Silverside. Official Name: EPA Test Method 1006.0: Inland Silverside, Menidia beryllina, Larval Survival and Growth Method.

Summary:
Inland Silverside, Menidia beryllina, 7 - 11 day old larvae are exposed in a static renewal system for 7 days to different concentrations of effluent or receiving water. Test results are based on the survival and growth of the larvae.

Scope:
This method estimates the chronic toxicity of effluents and receiving waters to the inland silverside, Menidia beryllina, using seven to eleven day old larvae in a seven day, static renewal test. The effects include the synergistic, antagonistic, and additive effects of all the chemical, physical, and biological components which adversely affect the physiological and biochemical functions of the test species.

Citation:
USEPA, October 2002, Short-Term Methods for Estimating the Chronic Toxicity of Effluents and Receiving Waters to Marine and Estuarine Organisms. Third Edition. EPA-821-R-02-014.

Interferences:
Toxic substances on glassware, hardware, etc.; Low D.O.; pH extremes; predatory organisms

QC Requirements:
Acceptable side-by-side reference toxicant testing; 80% or greater survival in controls, with a 0.50 mg average dry weight at conclusion of test.

Maximum Holding Time:
Sample must be used within 24h

Media:
WATER

Subcategory:
Chronic Toxicity

Concentration:
Effluent: 5 and a control (required) Receiving Water: 100% receiving water (or minimum of 5) and a control (recommended)

Sample Prep:
Above

Precision:
Based on single and multi-laboratory precision data.

Detection:
Not Applicable

Revision Number:
Third Edition, October 2002