EPA Method 1637


EPA Method 1637 does not directly match ALS - Columbia's list of currently available methods. Please call for availability.


Method information displayed is provided for informational purposes only. No warranty (express or implied) is made as to the website accuracy, completeness, or applicability (such as the age of a method and whether or not it applies to your project). Please contact us for assistance. Analytical testing dots

PDF IconView Actual EPA Method 1637 (PDF File)


EPA Method 1637:
Determination of Trace Elements in Ambient Waters by Chelation and GFAA. Official Name: Determination of Trace Elements in Ambient Waters by Off-Line Chelation Preconcentration and Stabilized Temperature Graphite Furnace Atomic Absorption

Summary:
A sample is acidified and solubilized by gentle refluxing (if total recoverable elements are desired). Elements in the sample are concentrated using off-line chelating resin column. The concentrated extracts are analyzed using stabilized temperature graphite furnace atomic absorption (GFAA).

Scope:
This method determines dissolved elements in ambient waters at EPA water quality criteria (WQC) levels. It may also be used for determination of total recoverable element concentrations in these waters.

Citation:
EPA Method Guidance CD-ROM (includes MCAWW Methods, and most current EPA Methods)

Interferences:
(A) Contamination by carryover: Contamination may occur when a sample containing low concentrations of metals is processed immediately after a sample containing relatively high concentrations of these metals. To reduce rinse the sampling system between samples with dilute acid and reagent water.(B) Contamination by samples: Significant laboratory or instrument contamination may result when untreated effluents, in-process waters, landfill leachates, and other samples containing high concentrations of inorganic substances are processed and analyzed.(C) Contamination by indirect contact: Apparatus that may not directly come in contact with the samples may still be a source of contamination. It is imperative that every piece of the apparatus that is directly or indirectly used in the collection, processing, and analysis of ambient water samples be cleaned.(D) Contamination by airborne particulate matter: Samples may be contaminated by airborne dust, dirt, particles, or vapors from unfiltered air supplies; nearby corroded or rusted pipes, wires, or other fixtures; or metal-containing paint.(E) Spectral interferences: Spectral interferences caused by the absorbance of light by a molecule or atom that is not the analyte of interest or emission from black body radiation.(F) Matrix interferences: Matrix interferences caused by sample components that inhibit the formation of free atomic analyte atoms during the atomization cycle.(G) Memory effects (GFAA) : Results from analyzing a sample containing a high concentration of an element (typically a high atomization temperature element) that cannot be removed quantitatively in one complete set of furnace steps.(H) Competing chelators: Low recoveries may be encountered in the preconcentration cycle if the trace elements are complexed by competing chelators (humic/fulvic) in the sample or are present as colloidal material.(I) Memory effects (Chelating System; Preconcentration).

QC Requirements:
The minimum requirements consist of an initial demonstration of laboratory capability, analysis of samples spiked with metals of interest to evaluate and document data quality, and analysis of standards and blanks as tests of continued performance.

Maximum Holding Time:
6 months (after preservation)

Media:
WATER

Subcategory:
Inorganic

Concentration:
Not Available.

Sample Prep:
None.

Precision:
-

Detection:
MDL as determined by 40 CFR Part 136, Appendix B.

Revision Number:
Jan-96

Analytical testing dots


Examples:  8260
TO-15

Examples:  Dioxin
Mercury
Analytical testing dots


<-- Search All Test Methods



Suggestions? The test methods page continues to expand and improve. If you have suggestions for improvement, we would enjoy hearing from you. Please contact the webmaster here.


Analytical testing dots