EPA Method 2019


EPA Method 2019 does not directly match ALS - Columbia's list of currently available methods. Please call for availability.


Method information displayed is provided for informational purposes only. No warranty (express or implied) is made as to the website accuracy, completeness, or applicability (such as the age of a method and whether or not it applies to your project). Please contact us for assistance. Analytical testing dots

PDF IconView Actual EPA Method 2019 (PDF File)


EPA Method 2019:
Acute Toxicity Tests for Waters Using Rainbow Trout and Brook Trout. Official Name: EPA Test Method 20019.0: Rainbow Trout, Oncorhynchus mykiss, and Brook Trout, Salvelinus fontinalis, Acute Toxicity Tests with Effluents and Receiving Waters

Summary:
Early life stage Oncorhynchus mykiss and Salvelinus fontinalis are exposed to varying concentrations of effluent or receiving water in a static non-renewal, static-renewal, or flow-through system for a pre-determined amount of time (24, 48, or 96 h). The survival in each concentration is compared to the survival in the control to determine the concentration of effluent or receiving water lethal to 50% of test organisms.

Scope:
This procedure describes an acute toxicity test method for use in the National Pollutant Discharge Elimination System (NPDES) Permits Program to identify effluents and receiving waters containing toxic materials in acutely toxic concentrations. This method is also suitable for determining the toxicity of specific compounds contained in discharges. This test may be conducted in a central laboratory or on-site, by the regulatory agency or the permittee.

Citation:
Methods for Measuring the Acute Toxicity of Effluents and Receiving Waters to Freshwater and Marine Organisms. Fifth Edition, October 2002. EPA Volume 821-R-02-012

Interferences:
N/A

QC Requirements:
Routine reference toxicant testing

Maximum Holding Time:
36h

Media:
WATER

Subcategory:
Acute Toxicity

Concentration:
Effluents: 5 and a control (minimum) Receiving Water: 100% receiving water and a control (recommended)

Sample Prep:
Coarse filtration; Dechlorination

Precision:
Based on single and multi-laboratory precision data.

Detection:
N/A

Revision Number:
Fifth Edition, October 2002

Analytical testing dots


Examples:  8260
TO-15

Examples:  Dioxin
Mercury
Analytical testing dots


<-- Search All Test Methods



Suggestions? The test methods page continues to expand and improve. If you have suggestions for improvement, we would enjoy hearing from you. Please contact the webmaster here.


Analytical testing dots