EPA Method 314


Columbia Analytical may or may not offer testing by methods shown. Please contact us for our latest available methods. Analytical testing dots

PDF IconView Actual EPA Method 314 (PDF File)


EPA Method 314 Summary:
Perchlorate in Drinking Water by Ion Chromatography. Official Name: Determination of Perchlorate in Drinking Water Using Ion Chromatography

Description:
One milliliter of water is introduced directly into an ion chromatograph equipped with a guard column and a suppressor device. Perchlorate ions are separated and measured using an analytical column and a conductivity detector.

Scope:
This methods determines perchlorate in reagent water, surface water, ground water and finished drinking water. Specific IC columns and analytical conditions are specified but other columns and conditions may be used.

Citation:
Methods for the Determination of Organic and Inorganic Compounds in Drinking Water, Volume 1 (EPA/815-R-00-014)

Interferences:
(A) Contamination: Interferences may be caused by contaminants in the reagent water, reagents, glassware, and other sample processing apparatus that lead to discrete artifacts or elevated baselines.(B) Coelution: Direct chromatographic coelution, concentration dependent coelution, and ionic displacement effects (which can shift rentention times) can all cause interferences by coelution. It may be possible to overcome adjusting chromatographic conditions (e.g., changing columns), diluting the sample, or using pretreatment cartridges. Care must be taken when using these steps to ensure that analyses are not adversely effected. (C) Anions: Sample matrices with high concentrations of common anions such as chloride, sulfate, and carbonate may destabilize the baseline.(D) Carry over: Carry over peaks from one analysis to another may also cause interferences as false positives.

QC Requirements:
Initial Demonstration of Capability must show acceptable Demonstration of Accuracy (IDA) and Precision (IDP) and the Method Detection Limit (MDL) must be determined. Recovery for Laboratory Fortified Blanks (LFB) must be 85 - 115%. If samples have perchlorate levels that exceed the Matrix Conductivity Threshold (MCT) then pretreated LFBs must be used to reduce common anion levels and recovery must be 85 - 115%. Recovery of Laboratory Fortified Sample Matrix (LFM) samples or pretreated LFMs (when MCT is exceeded) must be 80 - 120%. Relative Percent Difference (RPD) for field or laboratory duplicates must be + or - 15%

Maximum Holding Time:
28 days

Media:
WATER

Subcategory:
Inorganic

Concentration:
4 - 400 ug/L

Sample Prep:
None

Precision:
Precision and accuracy were determined using 8 replicate measurements of fortified reagent water in a single laboratory (see Table 2 of the method), using the equipment and conditions specified in Table 1 of the method. Additional data are available in the method.

Detection:
The MDL was determined in a single lab using fortified reagent water according to the procedure at 40 CFR 136, Appendix B. The MDL for a specific matrix may differ from those listed, depending on the nature of the sample and the specific instrumentation used.

Revision Number:
Revision 1.0, November 1999.

Test Description:
Perchlorate in DW us

Report Number:
815/R-00-014

Instrument used for this test:
IC

Analytical testing dots
Columbia Analytical offers testing for method 314 at these laboratories:

Kelso Kelso, Washington Laboratory
Analytical testing dots


Examples:  8260
TO-15

Examples:  Dioxin
Mercury
Analytical testing dots



<-- Search All Test Methods



Suggestions? The test methods page continues to expand and improve. If you have suggestions for improvement, we would enjoy hearing from you. Please contact the webmaster here.


Analytical testing dots