EPA Method 351.4


ALS - Columbia offers EPA Method 351.4 testing at these laboratories:

Kelso Kelso, Washington Laboratory

Method information displayed is provided for informational purposes only. No warranty (express or implied) is made as to the website accuracy, completeness, or applicability (such as the age of a method and whether or not it applies to your project). Please contact us for assistance. Analytical testing dots

PDF IconView Actual EPA Method 351.4 (PDF File)


EPA Method 351.4:
TKN by ISE. Official Name: Nitrogen, Kjeldahl Total (Potentiometric, Ion Selective Electrode)

Summary:
A sample is digested according to one of three procedures (macro-Kjeldahl, micro-Kjeldahl, or Block Digestion) to convert total Kjeldahl nitrogen (TKN) into ammonia. Following digestion and cooling, distilled water is added to the digestion flask and the pH adjusted to between 3 and 4.4 by the addition of NaOH. The sample is cooled and transferred to a 100 mL beaker. NaOH-NaI-EDTA is added to the beaker, and the ammonia concentration is measured using an ion selective electrode (EDTA prevents precipitation of hydroxides, thereby preventing deposition on the electrode membrane).

Scope:
This method is applicable to the measurement of total Kjeldahl nitrogen (TKN) in drinking and surface water; domestic and industrial waste.

Citation:
Methods for the Chemical Analysis of Water and Wastes (MCAWW) (EPA/600/4-79/020)

Interferences:
(A) Metals: Interference from metals is eliminated by the addition of NaI.(B) Nitrate: High nitrate concentrations (> 10 times the TKN level) result in low TKN values because of reaction between nitrate and ammonia. The reaction can be prevented by the use of an anion exchange resin (chloride form) to remove the nitrate prior to TKN analysis.

QC Requirements:
None given.

Maximum Holding Time:
28 days (MCAWW, Table 1).

Media:
WATER

Subcategory:
Inorganic

Concentration:
0.03 to 25 mg-TKN/L.

Precision:
Precision and accuracy values were calculated using interlaboratory data from EPA-managed Water Pollution (WP) performance evaluation studies.

Detection:
-

Revision Number:
Issued 1978

Test Description:
Nitrogen,Ammonia (as N)(Colorimetric,Automated Phenate)/Nitrogen,Kjeldahl,Total (Potentiometric,ISE)

Analytical testing dots
At least 1 analytes can be tested by ALS - Columbia using EPA Method 351.4. Please contact us for all available analytes which can be tested by EPA Method 351.4.

AnalyteCAS Number
Nitrogen7727-37-9





Examples:  8260
TO-15

Examples:  Dioxin
Mercury
Analytical testing dots


<-- Search All Test Methods



Suggestions? The test methods page continues to expand and improve. If you have suggestions for improvement, we would enjoy hearing from you. Please contact the webmaster here.


Analytical testing dots