EPA Method 521


ALS - Columbia offers EPA Method 521 testing at these laboratories:

Kelso Kelso, Washington Laboratory

Method information displayed is provided for informational purposes only. No warranty (express or implied) is made as to the website accuracy, completeness, or applicability (such as the age of a method and whether or not it applies to your project). Please contact us for assistance. Analytical testing dots

PDF IconView Actual EPA Method 521 (PDF File)


EPA Method 521:
Determination of Nitrosamines in Drinking Water by Solid Phase Extraction and Capillary Column and Solid Phase Extraction and Capillary Column Gas Chromatography

Summary:
NDMA is an emerging drinking water contaminant that is of interest to EPA and the environmental community. Its presence in drinking water is a potential health concern, because the EPA's IRIS data base lists the concentration of NDMA required to result in a one in one million lifetime cancer risk to be only 0.7 ng/L. NDMA is produced by industrial sources, such as the manufacture of rocket fuel, but has also been identified as a potential disinfection by-product. The focus of NERL's research was to develop an improved analytical method for the analysis of NDMA in drinking water that was sensitive, specific and cost-effective. Existing methods for measuring NDMA in water are expensive and labor intensive, and some require the use of very large amounts of toxic solvents such as methylene chloride. In addition, the sensitivity of some existing methods is insufficient for conducting low-level monitoring. The method was developed for inclusion in EPA's Unregulated Contaminant Monitoring Rule, scheduled for proposal in 2005, in order for the EPA Office of Water to collect nationwide occurrence data on nitrosamines in drinking water and make a regulatory determination. If NDMA or other nitrosamines become regulated drinking water contaminants in the future, the method could also be used for compliance monitoring.

Scope:
This method provides procedures for the determination of nitrosamines in finished drinking water. The method may be applicable to untreated source waters and other types of water samples, but it has not been evaluated for these uses. The method is applicable to nitrosamines that are efficiently partitioned from the water sample onto a solid phase extraction (SPE) sorbent, and sufficiently volatile and thermally stable for gas chromatography.

Citation:
Munch, J. W. METHOD 521: DETERMINATION OF NITROSAMINES IN DRINKING WATER BY SOLID PHASE EXTRACTION AND CAPILLARY COLUMN GAS CHROMATOGRAPHY WITH LARGE VOLUME INJECTION AND CHEMICAL IONIZATION TANDEM MASS SPECTROMETRY (MS/MS). U.S. Environmental Protection Agency, Washington, DC, 2005.

Revision Number:
11/30/2005

Test Description:
Nitrosamines In DW By SPE And Capillary Column GC With LVI And Chemical Ionization Tandem MS (MS/MS)

Report Number:
103912

Date Issued:
05/17/2005

Instrument used for this test:
MS/MS

Analytical testing dots


Examples:  8260
TO-15

Examples:  Dioxin
Mercury
Analytical testing dots


<-- Search All Test Methods



Suggestions? The test methods page continues to expand and improve. If you have suggestions for improvement, we would enjoy hearing from you. Please contact the webmaster here.


Analytical testing dots