EPA Method 552.2


ALS - Columbia offers EPA Method 552.2 testing at these laboratories:

Kelso Kelso, Washington Laboratory

Method information displayed is provided for informational purposes only. No warranty (express or implied) is made as to the website accuracy, completeness, or applicability (such as the age of a method and whether or not it applies to your project). Please contact us for assistance. Analytical testing dots

PDF IconView Actual EPA Method 552.2 (PDF File)


EPA Method 552.2:
Determination of Haloacetic Acids and Dalapon in Drinking Water by Liquid-Liquid Extraction, Derivatization and Gas Chromatography with Electron Capture Detection - Revision 1.0.

Summary:
A 40-mL sample is adjusted to a highly acidic pH and extracted with methyl tert-butyl ether (MTBE). The haloacetic acids that have been partitioned into the MTBE phase are then converted to their methyl esters by the addition of acidic methanol followed by slight heating. The acidic extract is neutralized by a back extraction with a saturated solution of sodium bicarbonate. The concentrations of acids in the extract are measured using a capillary column gas chromatography (GC) system equipped with an electron capture detector (ECD).

Scope:
This method determines haloacetic acids in drinking water, ground water, raw source water, and water at any intermediate treatment stage.

Citation:
Methods for the Determination of Organic Compounds in Drinking Water - Supplement III (EPA/600/R-95-131)

Interferences:
(A) Glassware contamination: Thoroughly clean glassware, including baking or solvent rinse.(B) Extracted interferences: Interference from extracted non-target compounds, with retention times similar to target compounds, can be reduced using confirmation analysis.(C) Memory Interferences: Carryover may occur whenever high and low concentration samples are analyzed in sequence. Rinse the sample syringe and associated equipment with MTBE between samples. Also, unusually concentrated samples should be followed by one or more injections of MTBE to ensure accurate values for the next sample.(D)Bromochloroacetic acid coelutes with an interferant (probably dimethyl sulfide) on the DB-1701 confirmation column. Quantitative confirmation can be performed by manual integration that includes only the peak area of the target ester.(E) Methylation using acidic methanol results in a partial decarboxylation of tribromoacetic acid. Therefore, a substantial peak for bromoform will be observed in the chromatograms. Its elution does not interfere with other analytes.

QC Requirements:
Laboratory performance check standard, initial demonstration of laboratory capability, method detection limit (MDL) determination, analysis of laboratory reagent blanks (LRBs), continuing calibration check standard, laboratory fortified sample matrices, field duplicates, and monitoring surrogate and/or internal standard peak response in each sample and blank. Additional QC practices may be added.

Maximum Holding Time:
14 days; extracts within 7 days if stored at 4oC or 14 days if stored at -10oC or less.

Media:
WATER

Subcategory:
Organic

Concentration:
Ranges differ depending on matrix and instrumentation used for detection.

Precision:
Precision and accuracy values were calculated using data from seven replicate analyses of fortified reagent water. Additional data are available in the method.

Detection:
MDLs were determined using the standard deviation of 8 replicate analyses of an analyte-fortified reagent water sample multiplied by the t-value for 7 degrees of freedom at the 99% confidence level. Detailed instructions for how MDLs are determined are found at 40 CFR part 136, Appendix B.

Revision Number:
Revision 1.0, 1995

Test Description:
Haloacetic Acids & D

Report Number:
600/R-95-131

Instrument used for this test:
GC

Analytical testing dots
At least 8 analytes can be tested by ALS - Columbia using EPA Method 552.2. Please contact us for all available analytes which can be tested by EPA Method 552.2.

AnalyteCAS Number
2,3-Dibromopropionic Acid600-05-5
4,4'-Dibromooctafluorobiphenyl10386-84-2
Bromoacetic Acid79-08-3
Chloroacetic Acid79-11-8
Dibromoacetic Acid631-64-1
Dichloroacetic Acid79-43-6
Haloacetic Acids, TotalCASID30309
Trichloroacetic Acid76-03-9





Examples:  8260
TO-15

Examples:  Dioxin
Mercury
Analytical testing dots


<-- Search All Test Methods



Suggestions? The test methods page continues to expand and improve. If you have suggestions for improvement, we would enjoy hearing from you. Please contact the webmaster here.


Analytical testing dots