EPA Method 9056A


ALS - Columbia offers EPA Method 9056A testing at these laboratories:

Kelso Kelso, Washington Laboratory
Rochester Rochester, New York Laboratory

ALS - Columbia offers the following EPA Method 9056 variations:

EPA Method 9056 testing is available at the Jacksonville Laboratory.
EPA Method 9056 testing is available at the Kelso Laboratory.
EPA Method 9056 testing is available at the Rochester Laboratory.
EPA Method 9056 testing is available at the Simi Valley Laboratory.
EPA Method 9056 testing is available at the Tucson Laboratory.

Method information displayed is provided for informational purposes only. No warranty (express or implied) is made as to the website accuracy, completeness, or applicability (such as the age of a method and whether or not it applies to your project). Please contact us for assistance. Analytical testing dots

PDF IconView Actual EPA Method 9056A (PDF File)


EPA Method 9056A:
Anion Chromatography Method. Official Name: Determination Of Inorgainic Anions By Ion Chromatography

Summary:
A small volume (2-3 mL) of sample is injected into an ion chromatograph to flush and fill a constant volume sample loop. The sample is then injected into a stream of carbonate-bicarbonate eluent of the same strength as the sample. The samples are passed through three ion exchange columns (with different functionalities), and compounds are identified by retention time, and quantitated by peak height or area (by comparison with a standard calibration curve).

Scope:
This method is applicable to the determination of chloride, fluoride, bromide, nitrate, phosphate, and sulfate in the collection solutions from the bomb combustion of solid waste samples, as well as all water samples.

Citation:
SW-846 Update IVB

QC Requirements:
Mid-range calibration standard every 10 injections; sample duplicate (1 in every 10 samples), MS

Maximum Holding Time:
ASAP

Media:
VARIOUS

Subcategory:
Inorganic

Concentration:
0.2 - 100mg/L. Ranges differ for each analyte. This range is taken from the lowest and highest limit of the analytes listed in the method.

Precision:
-

Detection:
Value corresponds to MDL determined per 40 CFR part 136, Appendix B.

Revision Number:
Revision 1, November 2000

Test Description:
Total Halogens

Analytical testing dots


Examples:  8260
TO-15

Examples:  Dioxin
Mercury
Analytical testing dots


<-- Search All Test Methods



Suggestions? The test methods page continues to expand and improve. If you have suggestions for improvement, we would enjoy hearing from you. Please contact the webmaster here.