Vapor Intrusion Investigations: Air Sampling Tips for Meeting Data Quality Objectives
Monday, September 26th, 2011N. Dagnillo1, L. Hill2, A. Fortune3, A. Smith4, and S. Thompson2
1Trihydro Corporation, 3001 E. Pershing Blvd, Suite 115, Cheyenne, WY 82007
2Trihydro Corporation, 1537 Riverside Ave., Suite 101, Fort Collins, CO 80524
3Columbia Analytical Services, Inc., 2655 Park Center Drive, Suite A, Simi Valley, CA 93065
4Trihydro Corporation, 9460 Calle Milano, Atascadero, CA 93422
Vapor intrusion is a fate and transport process characterized by the upward movement of volatile chemicals from subsurface contamination (e.g., buried waste, contaminated groundwater) into overlying buildings. The potential for adverse human health effects from exposure to indoor air vapors has motivated private, state, and federal entities to develop guidance documents and protocols specific to the collection and analysis of soil vapor data.

The Massachusetts Department of Environmental Protection (MassDEP) recently updated and finalized their Air-Phase Petroleum Hydrocarbons (APH) analytical method. The APH method, which had been in draft format since February 2000, was completed last year by a MassDEP Workgroup and approved after a month long public comment period in December 2008. The committee was comprised of MassDEP personnel, laboratory experts and data users. 
NEW! Allowable Levels Established for DEHP in Bottled Water
Vapor Intrusion Investigations: Air Sampling Tips for Meeting Data Quality Objectives
Incremental Sampling Methodology