How to Determine Metals Emissions by EPA Method 29

Monday, April 26th, 2010

By Ed Wallace, Project Chemist, Kelso, WAEPA Method 29

EPA Method 29 measures hazardous air pollutant (HAP) emissions from stationary sources for mercury and other metals. The Clean Air Act (CAA) requires all major sources to meet HAP emission standards reflecting the application of maximum achievable control technology (MACT). These sources include industrial, commercial, and institutional boilers and process heaters. The other metals to be tested are antimony, arsenic, barium, beryllium, cadmium, chromium, cobalt, copper, lead, manganese, nickel, phosphorus, selenium, thallium and zinc.