Instructional Video
Deployment and Retrieval of Passive Diffusion Bags (PDBs) in Groundwater Wells
Video Transcript:
- This video will show you how to deploy and retrieve Passive Diffusion Bags (PDBs).
- PDBs are used in the sampling of groundwater for Volatile Organic Compounds
- When you order a PDB device from Columbia Analytical, we can provide a hanging assembly that is labeled and presized to hang at the correct depth of your well screen.
- This is a standard size PDB prefilled with 220ml of certified ASTM type 2 DI water.
- Connect the bag to the top clip of the line.
- Then, secure at the bottom using a zip tie.
- Lower into well- the stop cap will set the bag at the desired depth.
- The PDB is now deployed.
- Retrieval is just as easy as deployment.
- After a minimum of 2 weeks, retrieve the line using the plastic winder.
- Unclip the top of the bag and cut the bottom zip tie.
- Using decontaminated scissors, cut a notch in the corner of the bag.
- Slowly pour the water into VOA vile; minimize agitation and ensure no headspace is left.
- Samples are then made ready for transport to the lab.
- PDBs are easy to use and cost effective.
- Learn more about PDBs on our website.
Call to Order: 1.800.695.7222
Columbia Analytical is a licensed manufacturer of passive diffusion samplers. We actively participate in the Interstate Technology Regulatory Council (ITRC) and have been instrumental in technological and regulatory advancements in this field.