USGS Test Method I-2302


Method information displayed is provided for informational purposes only.
ALS - Columbia may or may not offer methods shown. Please contact us to learn about ALS - Columbia's latest available methods. No warranty (express or implied) is made as to the website accuracy, completeness, or applicability (such as the age of a method and whether or not it applies to your project).

Analytical testing dots

PDF IconView Actual USGS Method I-2302 (PDF File)


Source:
USGS

Method Name:
Cyanide, whole water recoverable; colorimetric. Official Name: Cyanide, colorimetric, barbituric acid, automated-segmented flow

Description:
This method is based on the chlorination of cyanide with chloramine-T and on the subsequent reaction with a pyridine-barbituric acid reagent (Goulden and others, 1972). This method detects simple cyanides only; therefore, any complex cyanides must first be broken down by passing the acidified sample solution through an ultraviolet digestion-distillation procedure. The distillation step also removes certain interferences.

Scope:
This method may be used to analyze water and water-suspended sediment containing from 0.01 to 0.30 mg/L cyanide. Samples containing more than 0.30 mg/L need to be diluted. Total recoverable cyanide in water-suspended sediment can be determined if each sample is shaken vigorously and a suitable aliquot of well-mixed sample withdrawn. This method may be used to determine cyanide in bottom material containing at least 0.5 mg/kg.

Citation:
Methods for the Determination of Inorganic Substances in Water and Fluvial Sediments, Techniques of Water-Resources Investigations of the United States Geological Survey, Book 5, Chapter A1 Edited by Marvin J. Fishman and Linda C. Friedman

Interferences:
Chloride interferes if its concentration exceeds 3,000 mg/L. Oxidizing agents may interfere. Glycine and urea at the 10-mg/L level do not interfere. A concentration of 10 mg/L sulfide increases the apparent cyanide concentration by approx 0.02 mg/L. Concentrations of sulfide greater than 10 mg/L interfere considerably. Thiocyanate is broken down to cyanide and sulfide by this procedure and, therefore, interferes on an equimolar basis. Sulfate concentrations of 4,000 mg/L do not interfere. Higher concentrations were not tested.

QC Requirements:
Calibrate instrument using calibration standards (CAL). Quality control samples (QCS) and laboratory blanks (LB) analyzed at a minimum of I each after every 10 samples

Maximum Holding Time:
180 days

Media:
WATER

Subcategory:
Inorganic

Concentration:
0.010 - 0.30 mg/L

Precision:
-

Detection:
None.

Revision Number:
1985

Analytical testing dots

Related Methods:
Test Method 500001    Test Method 500007    Test Method 500021    Test Method 500061    Test Method 500071    Test Method 500076    Test Method 500081    Test Method 500086    Test Method 500090    Test Method 500201   


<-- Search again



*Method information displayed is provided as a convenience only. No warranty (express or implied) is made as to its accuracy, completeness, or applicability (such as the age of a method and whether or not it applies to your project).

Suggestions? The test methods page continues to expand and improve. If you have suggestions for improvement, we would enjoy hearing from you. Please contact the webmaster here.


Analytical testing dots